ASTM D5034 PDF

ASTM D5034 PDF

ASTM International ASTM D Tearing Strength of Fabric by . ASTM International. D Breaking Strength/Elongation Grab Method. ASTM D is a testing standard for determining the breaking strength and elongation of woven, non-woven, and felted fabrics and textiles. ASTM D is a popular testing standard for those needing to determine the breaking strength and elongation of fabrics and textiles.

Author: Daigami Malarn
Country: Myanmar
Language: English (Spanish)
Genre: Love
Published (Last): 8 December 2011
Pages: 174
PDF File Size: 6.57 Mb
ePub File Size: 14.53 Mb
ISBN: 857-1-18483-788-7
Downloads: 2405
Price: Free* [*Free Regsitration Required]
Uploader: Arasar

Special precautionary measures are provided for use when necessary for strong fabrics. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.

The method specifies a procedure to determine the maximum force and the elongation at maximum force of textile fabrics using a grab method.

Provisions are made for wet testing. The test specimens should then be randomly assigned in equal numbers to each laboratory for testing. SI units is the technically correct name for the system of metric units known as the International System of Units.

For the determination of the breaking force and elongation of textile fabrics using the raveled strip test procedure and the cut strip test procedure, refer to Test Method D If a bias is found, either its cause must be found and corrected, or the purchaser and the supplier must agree to interpret future test results in light of the known bias. WaveMatrix 2 for Dynamic Testing.

How can we help you? Inch-pound units is the technically correct name for the customary units used in the United States.

Subscribe to Instron News! Adjustable grip pressure also allows users to fine-tune aastm gripping pressure to avoid jaw breaks or slippage. Grab test specimens require much less time to prepare although they require more fabric per specimen.

The values stated in either acceptable metric units or in other units shall be regarded separately as standard. Users of previous versions of software such as Bluehill 2 and Bluehill 3 can d50334 upgrade to the newest version of Bluehill. A grab test is a tensile test in which only the center part of the specimen not the full width is gripped in the jaw faces.

  GLOMERULONEFRITE AGUDA PEDIATRIA PDF

Pneumatic side action grips with rubber coated jaw faces are well suited for clamping of the grab specimens. Historical Version s – view previous versions of standard. Discover simpler and smarter testing with features such as pre-loaded test methods, QuickTest in seconds, enhanced data exporting: The breaking force determined by the grab procedure is not a reflection of the strength of the yarns actually gripped between clamps and cannot be used for direct comparison with yarn strength determinations.

Bluehill Universal Software is built from the ground-up for touch interaction and an intuitive user experience. Next Checking to see if you are a returning visitor…. The values stated in either acceptable metric units or in other units shall be regarded separately as standard.

Email addresses must contain the symbol. SI units is the technically correct name for the system of metric units known as the International System of Units. Even then the data may differ significantly. Active view current version of standard. As a minimum, the two parties should take a group of test specimens which are as homogeneous as possible and which are from a lot of material astj the type in question. By continuing to use our site, you accept our cookie policy.

Work Item s – proposed revisions of this standard. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.

This standard mainly applies to most woven textile fabrics, but can be applicable to fabrics produced by other techniques. There is no simple relationship between grab tests and strip tests since the amount of fabric assistance depends on the atsm of fabric and construction variables. Inch-pound units is the technically correct name for the customary units used in the United States. Check this box to receive pertinent commercial email from Instron focusing on products, upcoming events, and more!

Bluehill LE for Basic Testing.

Competent statistical assistance is recommended for the investigation of bias. Software for Series Systems. This is because when individual fibers within the fabric fail, the data rate must be fast enough to catch these peaks. We use cookies to improve your browsing experience. Provisions are made for wet testing. Link to Active This link will always route to the current Active version of the standard.

  IMPERIAL ARMOUR THE ANPHELION PROJECT PDF

For this test, it is important to have an increased test data rate to ensure the capture a high number of data points. Glossary of Materials Testing Terms.

ASTM D5034 Textile Strength and Elongation Grab Test

Rapid data capture rate Specimen gripping Instron’s Solution: The challenges of testing to this standard are: The values stated in each system may not be exact equivalents; therefore, each system must be used independently of the other, without combining in any way. It is the responsibility of the user of this standard to establish appropriate safety, health and environmental practices and determine the applicability of regulatory limitations prior to use.

Link to Active This link will always route to the current Active version of the standard. Rapid data capture rate with Instron’s controller allows data peaks and valleys to be captured accurately at up to 2, points per second Instron pneumatic side action grips with rubber faces are well-suited to gripping nearly all types of fabric specimens for this test while maintaining high throughput It is important to review ASTM D in order to fully understand the test setup, procedure, and results requirements.

The values stated in each system may not be exact equivalents; therefore, each system must be used independently of the other, without combining in any way.

ASTM D Breaking Strength and Elongation of Textile Fabrics Grab Test – Instron

Contact Us View Accessories Catalog. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Onsite Training At Your Facility. It is important to review ASTM D in order to fully understand the test setup, procedure, and results requirements.

The average results from the two laboratories should be compared using Student’s t -test for unpaired data and an acceptable probability level chosen by the two parties before testing is begun.